1.4 Specifications
Cellular Interface
Standards: GSM/GPRS/EDGE
GPRS: max. 86 kbps (DL & UL), class 10
EDGE: max. 236.8 kbps (DL & UL), class 12
UMTS: max. 384 kbps (DL/UL)
Frequency: 850/900/1800/1900 MHz for GPRS/EDGE
900/2100 MHz for UMTS
CSD: Up to 14.4 kbps
Output Power: 1 watt GSM1800/1900
2 watts EGSM 900/GSM 850
SIM: 2 x (3V & 1.8V)
Antenna Interface: SMA Female, 50 ohms impedance
Serial Interface
Number of Ports: 1 x DB9 Female
Serial Standards: RS232 and RS485 selectable by software
ESD Protection: 15KV
Parameters: 8N1, 1200bps to 115200bps
Flow Control: RTS/CTS, XON/XOFF
RS-232: TxD, RxD, RTS, CTS, GND
RS-485: Data+ (A), Data- (B), GND
System
LED Indicators: 6 indicators, PWR, RUN, NET and 3 level RSSI
Real Time Clock: Built-in real time clock with button battery
Watchdog and Timer: Built-in watchdog and timer